11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
F-2600 & F-2700 Vortex Flow Meter Manual 02/15 - 0808-7 / 19204 Page A-9
METER ORDERING INFORMATION
Insertion Vortex Meter Codication = F-2700-ABC-DEFG
A = Connection Type
0 = 2” Male NPT threads with retractor
1 = 2” ANSI class 150 ange with retractor
3 = 2” ANSI class 300 ange with retractor
6 = 2” ANSI class 600 ange with retractor
7 = 2” Male NPT threads without retractor (50psig maximum pressure)
8 = 2” ANSI class 150 ange without retractor (50psig maximum pressure)
9 = 2” ANSI class 300 ange without retractor (50psig maximum pressure)
B = Integral or Remote Mount Transmitter
1 = Integral Mount
2 = Remote Mount
C = Temperature / Pressure Compensation
0 = Integral temperature compensation
1 = Integral temperature & pressure sensor, 30 psia maximum
2 = Integral temperature & pressure sensor, 100 psia maximum
3 = Integral temperature & pressure sensor, 300 psia maximum
4 = Integral temperature & pressure sensor, 500 psia maximum
9 = None
D = Input Power
0 = Loop powered (Only available with Output Signals option F=0)
1 = External 12-36 VDC powered
2 = External 85-240 VAC powered
E = Output Signals
0 = 4-20mA output*, pulse output & frequency output
1 = 4-20mA output, pulse output & frequency output, alarm output & MODBUS
2 = 4-20mA output, pulse output & frequency output, alarm output & BACnet
3 = (3) 4-20mA outputs, (3) alarm outputs, (1) pulse output (1) frequency output & MODBUS
4 = (3) 4-20mA outputs, (3) alarm outputs, (1) pulse output (1) frequency output & BACnet
5 = (3) 4-20mA outputs*, (3) alarm outputs, (1) pulse output (1) frequency output
6 = 4-20mA output*, pulse output & frequency output, alarm output
F = Maximum Operating Temperature
0 = 500° F
1 = 750° F
G = Energy Meter
0 = None
1 = Gross energy meter
2 = Net energy meter (requires additional remote temperature sensor.)
* Available with HART
®
serial communications
Remote Temperature Sensor and Thermowell Installation Kit
(Required for Net Energy Meter)
Part Number Description
20100 Remote Temperature Sensor, 1,000 Ohm 4-wire Class A Platinum RTD
20101 Remote Thermowell Kit for 1½" Welded Steel Pipe
20102 Remote Thermowell Kit for 2 - 5" Welded Steel Pipe
20103 Remote Thermowell Kit for 6 - 14" Welded Steel Pipe
Note: Net energy meter requires 1 temperature sensor and 1 thermowell installation kit sized to pipe.