Onicon F-5200 Inline Manual do Utilizador Página 13

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 20
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 12
11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
F-5200 Inline Thermal Mass Flow Meter Manual 05/14 - 0763-4 / 19476 Page 13
Installation Instructions
1. Thoroughly clean all ange surfaces removing all traces of any old gasket material or any
adhesive residue.
2. Inspect all ange surfaces for warping, pitting or other surface imperfections that may
prevent a good seal.
3. Use new bolts, nuts and hardened washers. Prior to installation, lubricate the bolt
threads, nuts, washer faces and the underside of each bolt head with lubricant (Fel Pro
C5A or equivalent). This lubricant is necessary to ensure uniform stress distribution on
the sealing surface. Use care not to get any lubricant on the gasket material.
4. Center the new gasket on the ange face. Do not allow the gaskets to protrude into the
ow stream.
5. Use the torque specications provided by the gasket manufacturer to determine the
proper torque setting.
6. Using a torque wrench, tighten the bolts in at least three stages (30%, 60% & 100%) using
a repeating pattern sequence of 12 o’clock to 6 o’clock to 3 o’clock to 9 o’clock around the
ange as shown in the diagrams below.
7. Leak test all connections.
Bolt Tightening Sequence