F-4000 Series Ultrasonic Flow Meter Manual 05/15 - 0707-13 / 18838 Page 11
Do not, if possible, install the transducers downstream from a throttling valve, a mixing tank,
the discharge of a positive displacement pump or any other equipment that could possibly
aerate the liquid. The best location will be as free as possible from ow disturbances,
vibration, sources of heat, noise, or radiated energy.
Avoid mounting the transducers on a section of pipe with any external scale. Remove all
scale, rust, loose paint, etc., from the location prior to mounting the transducers.
Do not mount the transducers on a surface aberration (pipe seam, etc.).
Do not mount transducers from different ultrasonic ow meters on the same pipe.
Do not run the transducer coaxial cables in common bundles with cables from other
instrumentation. You can run these cables through a common conduit ONLY if they originate
at the same ow meter.
Never mount transducers under water, unless you have specically purchased submersible
transducers and you install them in accordance with factory instructions.
Avoid mounting transducers on the top of a horizontal pipe. The best placement on a
horizontal pipe is either the 10:00 or 2:00 position for reect mode, or one sensor at 9:00 and
one sensor at 3:00 for direct mode.
Do not mount transducers on the bottom of a horizontal pipe.
Mounting on a vertical pipe is recommended only if ow is in the upward direction. When
mounting on a vertical pipe owing in a downward direction, make sure there is sufcient
back pressure in the system to maintain a full pipe.
IMPORTANT NOTE
In some cases, longer straight runs may be necessary where the transducers are placed downstream
from devices which cause unusual ow prole disruptions or swirl; for example, modulating valves
or two elbows in close proximity and out of plane, etc.
i
The Transducers
For best results, the transducers must be installed on a straight run of pipe, free of bends, tees,
valves, transitions, insertion probes and obstructions of any kind. For most installations, ten
straight unobstructed pipe diameters upstream and ve diameters downstream of the transducers
is the minimum recommended distance for proper operation. Additional considerations are
outlined below.
Flow
10 Dia. 5 Dia.